Fiber Optic Patch Cord, MPO/PC(F)-4xLC/PC(F), 8 Fibers, Multimode (OM3), Plenum (OFNP), Type B, Aqua

8F MPO/PC(F)-4xLC/PC(F)-OM3-3.0 Type B, Aqua
This mpo to lc breakout cable brings eight OM3 multimode fibers from one female MPO/PC connector to four LC/PC connection ends. Its Type B configuration is intended for compatible equipment and cabling designs where fibers need to be distributed from an MPO interface to LC connections. The aqua cable is listed with an OFNP-rated jacket.

Product Highlights
*8-Fiber OM3 Multimode Cable Assembly
*Female MPO/PC Connector to Four LC/PC Ends
*Type B Configuration for Compatible Channel Designs
*Breakout Construction for MPO-to-LC Connections
*Aqua OFNP-Rated Cable Jacket
Quantity:
Contact Now
add to cart

8-Fiber OM3 MPO-to-LC Breakout Cable, Type B

This om3 mpo breakout cable provides a transition from one MPO interface to four LC connection ends. Before installation, check the fiber mapping and connector requirements at both ends of the 8 fiber mpo to lc cable.

Specifications

Product Name
Fiber Optic Patch Cord
Brand
Firstoptic
Connector A
MPO/PC(F)
Connector B
LC Duplex
Polish TypeUPC to UPC
Polarity
Type B
Fiber Mode
OM3 50/125μm
Wavelength
850/1300nm
Material
LSZH
Cable Jacket
Plenum (OFNP)
Cable Outside Diameter
 (OD)
3.0mm
Breakout Outside Diameter (OD)2.0mm
Connector Durability
500 times
Tensile Strength
(Long/Short Term)
90/180N
Insertion Loss
≤0.25dB
Return Loss
≥20dB
Attenuation at 850 nm
≤3.0 dB/km
Attenuation at 1300 nm
≤0.7 dB/km
Operating Temperature
 -10 to 60°C (14 to 140℉)
Storage Temperature
 -10 to 70°C (14 to 158℉)
 

 

MPO-to-LC Breakout Configuration

The MPO end of this mpo to lc breakout cable combines eight fibers in one connector. At the opposite end, the fibers are distributed to four LC connection ends.

The MPO/PC connector is listed as female, without guide pins. Confirm the mating connector’s pin configuration and check the LC interface requirements before installation.

For this om3 mpo breakout cable, verify each branch’s fiber assignment against the equipment and channel design. Type B alone does not establish the correct transmit-to-receive connection.

mpo to lc breakout cable with one MPO connector and four duplex LC branches
 
 

Applications

This 8 fiber mpo to lc cable is intended for compatible OM3 multimode links where an MPO interface connects to LC interfaces:

  • MPO-to-LC connections between compatible network equipment
  • Connections through appropriately configured MPO and LC patch panels
  • OM3 cabling deployments requiring individual LC branches
  • Data center cabling routes specifying an OFNP-rated jacket

Before using this mpo to lc breakout cable with parallel-optics equipment, confirm the MPO connector type, populated fiber positions, LC branch mapping and supported OM3 link distance.

MPO patch panel cabling illustration for an om3 mpo breakout cable application
 

Standardized Production

Multiple processes, strict screening, quality assurance.
Polarity testing equipment for an mpo to lc breakout cablePolarity test
Insertion and return loss testing equipment for an om3 mpo breakout cableInsertion/return loss detection
Fiber end-face inspection equipment for 8 fiber mpo to lc cable quality checksEnd detection

  FAQ Section

Q1: What is the difference between an MPO-to-LC breakout cable and an MPO-to-MPO cable?

An MPO-to-MPO cable has an MPO connector at each end. This mpo to lc breakout cable has an MPO connector at one end and four LC connection ends at the other.


Q2: Can this om3 mpo breakout cable connect directly to any optical module?

No. Check the module’s connector type, fiber requirements and channel configuration. The presence of an MPO or LC interface alone does not establish compatibility.


Q3: How should the LC branches of this 8 fiber mpo to lc cable be connected?

Follow the assembly’s branch labels and fiber-mapping documentation. Confirm that the transmit and receive paths match the connected equipment.


Q4: What should be checked before ordering?

Confirm the total cable length, branch length, LC connector configuration, MPO connector gender, Type B mapping and OFNP jacket requirement.

Recommend Products

Send Message